Module structure of main and auxiliary contacts; small volume; and light weight.

OV140 series DC contactors can be applied for railway diesel locomotives, subway rolling stocks, EMU (electronic multiple units), DMU (diesel multiple units) and other industrial electric automation control equipment. Such DC contactors are used to control circuit in locomotives and rolling stocks.

 

The production standards comply with GB/T 21413.1-2008/IEC 60077-1:1999; GB/T 21413.2-2008/IEC 60077-2:1999; and TB/T 2767-1996.

 

Magnetic coil of such DC contactors is equipped with voltage suppressor which can inhibit the self-induced electromotive force of the coil. Working indicator light is equipped to show the working status of the contactor. Due to advanced contact module, auxiliary contact has fast-moving, self-cleaning and sealing characteristics.

 

Technical Parameters

Main Contact

 

Rated Voltage (Ue)

DC 110V

Conventional Thermal Current (Ith)

OV008P5 Ith = 25A

 

OV008P6 Ith = 40A

Auxiliary Contact

OV866 a/L, OV867 W1A2b

Rated Voltage (Ue)

DC 110V

Conventional Thermal Current (Ith)

DC 10A

Rated Current (Ie) (DC-13)

DC 1A

Protection Class (Pollution Level 3)

 

Whole Contactor & Auxiliary Contact Wiring

IP00

Auxiliary Contact

IP40 (OV866 a/L)

 

IP60 (OV867 W2A2b)

Coil Power

About 16W

Weight (excluding mounting base)

About 1.7 Kg

Mechanic Life

Over 106 times

Electric Life

Over 105 times

 

Models Selection

 

1-  Coil control voltage of OV140 series DC contactors can be DC 24V, 48V, 74V and 110V, and coil working voltage is between 80% and 110%.

2-  External wiring mode is below:

     Main Contact:     M6 Screw (OV140A-1 & OV140C-2 contactors)

                                M5 Screw (OV140A-2 & OV140C-1 contactors)

     Coil Wiring:         M4 Screw

     Auxiliary Contact: M3 Screw

3-  Generally, the contactor is equipped with 2 sets of main contact (2 NO, or 1 NO + 1 NC) and 2 sets of auxiliary contact (2 NO + 2 NC).

4-  When voltage suppressor is parallel connected to two ends of coil, wiring should be as per polarity signs.

5-  If main contact of the contactor is permanent magnet and in arc distinguishing mode, wiring should be as per polarity signs.

 

Wiring Diagram

 

Structural Size

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.