1.single phase 6KVA online ups manufacturer
2.OEM/ODM
3.cold start function
4.Hot-swappable battery design
5.LCD display
Outstanding Feature
1. Pure sine wave output ups power system
2. Tower / Rack multi-configuration for flexible installation
3. Microprocessor control guarantees high reliability
4. Adopting high frequency full bridge topology for high steady performance
5. High input power factor correction power system
6. Selectable various output range and operating mode
7. Cold start function ups power system
8. Inbuilt static bypass enhance better protection for critical load
9. Built-in dry contact/RS-232/EPO communication port
10. SNMP allows for web-based remote or monitoring management
11. Optional USB communication port
Technical specification
MODEL | S4KSL | S6KSL | |
Topology |
| On Line Double Conversion | |
Input | Support input type | Inverter, generator | Inverter, generator |
Input voltage range | 138V to 300V (0~60% load) | ||
138~161V to 300V (60%~80% load) | |||
161~184V to 300~286V (80%~100% load) | |||
Bypass voltage range | 230+/-10 %VAC (Adjustable) | ||
frequency | 50/60 Hz +/- 5 Hz (Auto sensing) | ||
connection | Hard Wire | ||
power factor | >0.98 @ full load | ||
Output | VA | 4KVA | 6KVA |
Watt | 2800W | 4200W | |
Voltage | 220/230/240Vac ± 1% | ||
Output waveform | Pure Sine Wave | ||
Harmonic distortion | THD< 3% @ linear load | ||
(Line Mode) | THD< =6% @ non-linear load | ||
Output frequency (Battery Mode) | 50 / 60Hz ±0.1Hz | ||
Current crest ratio | 3:01 | ||
Output connection | Hard wire | ||
Overload capacity | Line mode | ||
Over 110% for 2mins, then transfer to bypass and alarm. | |||
Over 150% for 1s, then transfer to bypass and turn off output after 1min and alarm. | |||
Battery mode | |||
Over 110% for 30s, then turn off output and alarm. | |||
Over 120%, for 1s, then turn off output and alarm | |||
Transfer time | AC to DC | 0 ms | |
Efficiency | Inverter mode | >93% | |
Battery mode | >92% | ||
ECO mode | >97% | ||
Battery | Battery type | 12V/5Ah*10ea | 12V/9Ah*12ea |
Backup time (Full Load) | 4min | 6min | |
Typical recharge time | 3 hours to 90% for Internal batteries; | ||
Charge current | 2A for Internal batteries; 6A max. (Adjustable) | ||
Temp. Compensation | Yes | ||
Communicate & Interface | Interface port(s) | RS232+Dry contact (DB9) /RJ45/SNMP Slot | |
Optional cards | SNMP Card/AS400 Relay Card | ||
LCD display | Information for Load / Battery / Input / Output and Operating Mode | ||
Audible alarm | Actively audible alarm for utility failed/ battery low /overload condition | ||
Silence switch | Yes | ||
EPO | Yes | Yes | |
Environmental | Noise level | <52dB@1Meter | <56dB@1Meter |
Operating temp. | 0-1,500m @ 0-40°C / 1,501-3,000m @ 0-35 °C | ||
Storage temp. | -20°C ~ 55°C | ||
Relative humidity | 0 ~ 95% humidity, non-condensing | ||
Operating elevation | 3,000 meters | ||
Physical | Installation | Rack & Tower (2-in-1) | |
Dimension (DxWxH) | 454x440x88mm | 454x440x132mm | |
Net weight (kg) | 12kg | 13.5kg |