Ozone Controller
Tongdy [China]
Model No: F2000IAQ-O3
Place of Origin: Beijing, China
Brand Name: Tongdy
Packaging: Full and firm package
Minimum Order: 20pcs
Quality/Safety Certification: ce
¨ Features
u Real time detect ambiance ozone gas level
u Detect temperature and humidity at the same time
u Wall mounted with LCD display
u LCD can display ozone, temperature and humidity,
also controlled device status etc.
u Ozone measured range:10ppb~500ppb;
Temperature range: 0~50℃ and relative humidity range:5~95%RH
u Semiconductor sensor inside, high sensitivity to ozone gas
u Special design compensation of ozone measurements for environment temp.&RH%
u Provide an easy zero calibration way
u Modbus RS-485 interface with 15KV antistatic protection, independent base address setting
u Optional 1X relay dry-contact output for an ozone generator or a fan optional
u Optional 1Xanalog linear output (0~10VCD) for the ozone measurement
ozone level
|
temperature
|
turn on/off
|
down up.
|
setting switch
|
humidity
|
relay on
|
¨ Buttons and LCD
¨ Specifications
Gas detected
|
Ozone gas
|
Sensing element
|
Semiconductor gas sensor
|
Life time of ozone sensor
|
More than 5 years
|
Temperature sensor
|
NTC5K
|
Humidity sensor
|
HS series capacitive sensor
|
Power supply
|
24VAC/VDC
|
O3 measuring range
|
10~500ppb (0.01~0.5ppm)
|
Display resolution
|
1 ppb
|
O3 measuring precision
|
±10ppb + 20% reading @10~50℃/20~90%RH
|
Temperature measurement range
|
0~50℃(32~122℉)
|
Humidity measurement range
|
5~95%RH
|
Warm up time
|
96 hours(first time) 1 hour(operation)
|
Analog output (option)
|
0~10VDC linear output
|
Output resolution
|
10Bit
|
Relay output (option)
|
One dry contact output to control an ozone device or a ventilation device
Rated switching current 2A resistance load
|
RS485 interface
|
Modbus protocol with 19200bps.
15KV antistatic protection, independent base address
|
Operation conditions
|
0~50℃/5~95%RH,non condensing
|
Storage conditions
|
5~50℃/5~90%RH,non condensing
|
Net Weight
|
260g
|
Dimensions
|
120mm×90mm×24mm
|
Installment standard
|
65mm×65mm or 2”×4” wire box
|
Wiring standard
|
Wire section area <1.5mm2
|
Approval
|
CE-Approval
|
¨ Models
Model
|
Characteristic
|
F2000IAQ-O3-1001C
|
Ozone monitor & controller with 1Xon/Off relay output, Modbus RS485 interface
|
F2000IAQ-O3-1010C
|
Ozone monitor & controller with 1X analog output. Modbus RS485 interface
|
F2000IAQ-O3-1011C
|
Ozone monitor & controller with 1Xon/Off relay output and 1X analog output.
Modbus RS485 interface
|
F2000IAQ-O3-1000C
|
Ozone monitor & controller with a Modbus RS485 interface
|
¨ Features
u Real time detect ambiance ozone gas level
u Detect temperature and humidity at the same time
u Wall mounted with LCD display
u LCD can display ozone, temperature and humidity,
also controlled device status etc.
u Ozone measured range:10ppb~500ppb;
Temperature range: 0~50℃ and relative humidity range:5~95%RH
u Semiconductor sensor inside, high sensitivity to ozone gas
u Special design compensation of ozone measurements for environment temp.&RH%
u Provide an easy zero calibration way
u Modbus RS-485 interface with 15KV antistatic protection, independent base address setting
u Optional 1X relay dry-contact output for an ozone generator or a fan optional
u Optional 1Xanalog linear output (0~10VCD) for the ozone measurement
ozone level
|
temperature
|
turn on/off
|
down up.
|
setting switch
|
humidity
|
relay on
|
¨ Buttons and LCD
¨ Specifications
Gas detected
|
Ozone gas
|
Sensing element
|
Semiconductor gas sensor
|
Life time of ozone sensor
|
More than 5 years
|
Temperature sensor
|
NTC5K
|
Humidity sensor
|
HS series capacitive sensor
|
Power supply
|
24VAC/VDC
|
O3 measuring range
|
10~500ppb (0.01~0.5ppm)
|
Display resolution
|
1 ppb
|
O3 measuring precision
|
±10ppb + 20% reading @10~50℃/20~90%RH
|
Temperature measurement range
|
0~50℃(32~122℉)
|
Humidity measurement range
|
5~95%RH
|
Warm up time
|
96 hours(first time) 1 hour(operation)
|
Analog output (option)
|
0~10VDC linear output
|
Output resolution
|
10Bit
|
Relay output (option)
|
One dry contact output to control an ozone device or a ventilation device
Rated switching current 2A resistance load
|
RS485 interface
|
Modbus protocol with 19200bps.
15KV antistatic protection, independent base address
|
Operation conditions
|
0~50℃/5~95%RH,non condensing
|
Storage conditions
|